| Drive | TX 40 |
|---|---|
| Diameter | Ø 7,4 mm |
| Lengths | 180-500 mm |
| Material | Specially coated steel |
| Coating | Blue zinc-plated |
Blue-Power system screw
400,84 zł - 1 871,85 zł incl. VAT
plus shipping costs
Shipping to the EU: 109,47 zł
Not sure which size? Call us: +48 22 266 21 23
- Drive
- TX 40
- Diameter
- Ø 7,4 mm
- Lengths
- 180-500 mm
- Coating
- Blue zinc-plated
- Material
- Specially coated steel
- Size
- 7,4 x 180 mm · 7,4 x 200 mm · 7,4 x 220 mm …
- Packaging
- 100 pcs
Article numbers and dimensions
Ordering by number? Below is the full list with the Eurotec article number and EAN.
| Art. no. | Size | Pack | EAN |
|---|---|---|---|
| 110390 | 7,4 x 180 mm | 100 pcs | 4251314700438 |
| 110391 | 7,4 x 200 mm | 100 pcs | 4251314700445 |
| 110392 | 7,4 x 220 mm | 100 pcs | 4251314700452 |
| 110393 | 7,4 x 240 mm | 100 pcs | 4251314700469 |
| 110394 | 7,4 x 260 mm | 100 pcs | 4251314700476 |
| 110395 | 7,4 x 280 mm | 100 pcs | 4251314700483 |
| 110396 | 7,4 x 300 mm | 100 pcs | 4251314700490 |
| 110397 | 7,4 x 320 mm | 100 pcs | 4251314700506 |
| 110398 | 7,4 x 340 mm | 100 pcs | 4251314700513 |
| 110399 | 7,4 x 360 mm | 100 pcs | 4251314700520 |
| 110400 | 7,4 x 380 mm | 100 pcs | 4251314700537 |
| 110401 | 7,4 x 400 mm | 100 pcs | 4251314700544 |
| 110404 | 7,4 x 450 mm | 100 pcs | 4064827055328 |
| 110407 | 7,4 x 500 mm | 100 pcs | 4064827055335 |
All data sheets: Facade fastening
The Blue-Power system screw fixes the timber substructure of a facade to concrete and masonry - at a distance, without a metal console. It carries both tensile and shear loads, and on an insulated facade the insulation itself takes part of the load.
Two conditions without which the system does not work: the insulation must have a compressive strength of at least 50 kPa at 10 % deformation, and the C24 timber battens a cross section of at least 30 x 50 mm. Softer insulation or thinner battens will not take the shear forces the system is designed for.
The permissible insulation thickness depends on the substrate, not only on the length of the screw - and on this item that is the most expensive mistake. The same 7.4 x 180 mm screw holds 100 mm of insulation in concrete and solid brick, 80 mm in aerated concrete and hollow calcium silicate block, but only 30 mm in vertically perforated brick. Seventy millimetres of difference on a single article number.
The ladder runs to fourteen lengths from 180 to 500 mm, all Ø 7.4 mm with a TX 40 drive. In concrete it covers insulation from 100 to 340 mm, in aerated concrete from 80 to 360 mm, and in vertically perforated brick from 30 to 290 mm. The full length-substrate-insulation table is in the datasheet, downloadable without login.
Blue-Power or EiSYS-2 - which one when. EiSYS-2 has a rotating sleeve under the head, so the facade plane is set after driving; that is the choice for a wall with deviations. Blue-Power has fixed geometry and is simpler where the substrate is even and what matters is carrying the load at a distance.
Blue-Power fixes the battens, not the cladding - the cladding board goes onto the battens with a separate fastener.
Parameters: sizes 7,4 x 180-500 mm, drive TX 40, pack 100 pcs. Article numbers and EAN codes for every size are listed in the table below.
Stock items dispatched from Poland within 24 h, items on order: 5-7 working days. VAT invoice with every order. Delivery after dispatch: 1-2 working days within Poland, 3-7 working days to other EU countries.
Manufacturer
E.u.r.o.Tec GmbH
Unter dem Hofe 5
58099 Hagen, Germany
[email protected] · eurotec.team
Product identification
Product name, article number and EAN - in the number table on this page. The batch number is on the packaging.
Safety information
- Use the product as intended and in line with the manufacturer's documentation (product data sheet, installation guide, European Technical Assessment - where applicable). The documents can be downloaded on this page.
- Load-bearing connections must be designed and checked by a qualified person. Do not exceed the values given in the documentation.
- Parts may have sharp tips and edges - wear gloves and safety glasses during installation.
- Store in a dry place, out of the reach of children.
Read before you buy
- Guide: Fixing and levelling facade battens through insulation - EiSYS-2How to choose the EiSYS-2 screw length, what the plug and tool are for, and when…
- Guide: Timber cladding substructure - a ventilated facade step by stepLayers, batten direction, counter-battens, the ventilation gap and fixings - how to build the substructure for…
- Guide: A2 or A4 - which stainless steelA2 for ordinary outdoor conditions, A4 where chlorides are present. And one place where neither will…



Partner